Home
Contact
Account/Profile
Basket

How to install the LS16 letter chute into a wall being built

6 Steps to fitting your LS16 Oakley letter chute assembly into a brick wall being built

Letterplate and chute assembly for Oakley letter chute

Step 1

Insert the grub screws into the threaded inserts of the letterplate then secure to the front sleeve using the 2 nylocs.

Oakley letter chute securing bolts

Step 2

The rear chute has 2 sets of securing holes, the set required will depend on the depth of the wall. The diagram shows the set used for deeper walls. Place 2 nylon washers onto each of the 4 securing bolts and loosely screw into the securing holes. Position the washers as shown.

 

Oakley letter chute assembly

Step 3

Slide the 2 sections together ensuring that the securing bolts locate in the adjusting slots with a nylon washer either side of the section. Set the overall depth of the chute to  the thickness of the wall and lock the securing bolts up with the 5mm allan key.

Seal letter chute sections with silicon

Step 4

Slide Run a bead of silicon around the join of the front and rear sections.

Brick wall for letter chute

Step 5

Build the brickwork up to the levels of the chute assembly.

Use the chute assembly as a guide and cut the bricks to shape. The slope on the rear wall is not critical but the front wall needs to be reasonably good. The slope angle is 28 degrees.

Note the notch cutouts on the front wall, the dimensions are shown below

 

  • D = 15mm, the depth of the notch
  • W = 20mm, the width of the notch
     

It is advised that a membrane is fitted above the chute and sealed on the 2 edges in contact with the walls.

 

Use Letter chute for guide
Insert a membrane above letter chute
LS16 Chute assembly in a brick wall

Step 6

Continue to build the wall around the letter chute.

After the brickwork has set, run a neat bead of clear silicon around the top and sides where the letterplate meets the brickwork. Do not apply to the bottom edge.

 

Click here to return to LS16 Oakley Letter Chute

Mailbox Manufacturers

Lettasafe manufacture their entire range of post boxes in their workshops in South Burlingham. All the letterbox components* are made in England. The front and back castings including the post flap and door of our post boxes are cast from solid aluminium in English foundries. The mailbox sleeve is made from sturdy zintec coated steel. All the postb...

Lockable Letter Boxes

KEY FEATURES Key Lockable Robust Cast Aluminium Mail Retrieved Securely From the Rear Securely fits to Railings Anti Theft Restrictor Plate Available All the Lettasafe post boxes have a standard set of security features which include a snap action lock which is supplied with 2 keys. The mail box front and rear castings incl...

How to order your LS05 Postbox for Metal Gates and Railings

Helpful tips for ordering an LS05 post box for fitting into metal gates and railings Choose your postbox colour   Select one of the 4 letterbox colours.   Choose your postbox case size (the depth from front to back)   Stand...

How to install the LS12 Mailbox into an existing wall

7 Steps to fitting your LS12 Thames postbox into an existing brick wall Step 1 Cut a hole in the front wall at the required height. A = 407mm, the height of the side of the opening H = 427mm, the height to the top of the apex W = 299mm, the width of the opening...

How to Install the LS12 Thames letterbox into a wall being built

4 Steps to fitting your LS12 Thames postbox into a brick wall being built Step 1 Build the wall up to the required height then build in the containing section of the mailbox, the bottom should be started on a new course of bricks and be bedded into cement. Note: If the slate front is to be proud o...

How tom install your LS16 into an existing wall

6 Steps to fitting your LS16 Oakley letter chute assembly into an existing brick wall Step 1 Insert the grub screws into the threaded inserts of the letterplate then secure to the front sleeve using the 2 nylocs. Step 2 Cut a hole 252mm wide by 77mm high at the requir...

How to install the LS16 letter chute into a wall being built

6 Steps to fitting your LS16 Oakley letter chute assembly into a brick wall being built Step 1 Insert the grub screws into the threaded inserts of the letterplate then secure to the front sleeve using the 2 nylocs. Step 2 The rear chute has 2 sets of securing hol...

How to fit your LS17 into an existing brick wall

6 Steps to fitting your LS17 Highway letter chute assembly into an existing brick wall Step 1 Insert the grub screws into the threaded inserts of the letterplate then secure to the front sleeve using the 2 nylocs. Step 2 Cut a hole 296mm high by 79mm wide at the requi...

How to Install your LS17 Postbox into a wall being built

7 Steps to fitting your LS17 Highway letter chute assembly into a brick wall being built Step 1 Insert the grub screws into the threaded inserts of the letterplate then secure to the front sleeve using the 2 nylocs. Step 2 The rear chute has 2 sets of securing holes,...

How to order your LS05 Postbox for a Brick Wall

Shown below are some useful tips for ordering an LS05 letterbox when being built into a brick wall. Choose your letterbox colour Select one of the 4 letterbox colours. Choose your letterbox case size (the depth from front to back) Standard Depth Case The standar...

Helpful tips for ordering an LS05 post box for fitting into metal gates and railings

Helpful tips for ordering an LS05 post box for fitting into metal gates and railings  Choose your postbox colour   Select one of the 4 letterbox colours.       Choose your postbox case size (the depth from front to back)...

How to install the LS13 Orwell letter chute into a wall being built

7 Steps to fitting your LS13 Orwell letter chute assembly into a brick wall being built   Step 1 Build the wall up to the height of the letter plate. Leave a gap of 260mm wide on the front face as illustrated. Note: The bricks either side of the gap will need to be removed to be notched (See step 2). W = 260mm   &...

How to Install your LS13 Letter Chute assembly into an existing brick wall

6 Steps to fitting your LS13 Orwell letter chute assembly into an existing brick wall       Step 1 Cut a hole as illustrated on the front wall at the required location of the letter plate. W = 260mm, H = 88mm                   &nb...

Buying a new Letterbox

Buying a new Postbox Letterboxes come in all different shapes and sizes, so when looking for a new letter box it’s a good idea to have an understanding of what you require from it, and how you want it to fit within your surroundings. To start with, you will need to take into account the type of property for which you will be purchasing the...

How to Install your LS15 Hampton Letterbox

6 Steps to fitting your LS15 Hampton Letterbox into a brick wall       Step 1 Cut (or leave a hole if building) as illustrated on the front wall at the required location of the letter plate. W = 88mm, H = 260mm                Step 2...

Wall Mounted Letter Boxes

KEY FEATURES.   Securely Fitted to Walls and Fences Key Lockable Secure Cast Aluminum front and rear castings Finished in Textured Powder Coat Enamel Anti Theft Restrictor Plate Available   Lettasafe manufacture a range of postboxes designed to be mounted on to walls , fences and railings. The mailbox is fixed w...
Close